TCA100 SMPTE Timecode Distribution Amplifier

The TCA100 is a dual-channel time code distribution amplifier for SMPTE, EBU and IRIG.

Masterclock TCA100 distribution amplifier with SMPTE LTC timecode and BNC connectors

Two separate output channels, each with its own level control on the front panel, available on BNC and on the DB-9 connector. Jumpers inside the case select a transformer-isolated differential, single-ended grounded or balanced isolated output. For studio and broadcast installations where connected equipment sits at different ground potentials.

Technical specifications

Standard Features
  • Works with SMPTE, EBU and IRIG time codes
  • Transformer outputs for superior isolation
  • BNC I/O connectors for ease of connection
  • Balanced I/O available via DB-9 connector
  • Two separate and isolated output channels
Output Options
  • isolated balanced to ground
  • single ended grounded
  • transformer isolated differential
Output Level
  • Up to 14 V PP (with 600O load)
  • Each channel is individually adjustable with a front panel accessible level control
Input Level
  • 2-14 Vpp range of input for rated output
I/O Connections
  • Balanced input via isolated BNC or 2 pins of DB-9 male connector
  • Tansformer isolated, balanced outpute via isolated BNC or separate DB-9 connector pins
  • 2 mm male power plug
Physical
  • Size: 10.6w x 3.8h x 14d cm
  • Weight: 435g
Frequency Response
  • 100 Hz to 8 kHz ± 1 dB
Power
  • Input voltage: 12-28 VDC
  • Power consumption: < 1W
  • External wall mount 120 or 220 VAC power supply
Operating Parameters
  • Temperature: 0 to 60°C
  • Humidity: Up to 90% (non-condensing)
Warranty
  • 1 year Daylight warranty + 4 years extra Masterclock warranty (parts and labour)
Compliance
  • FCC, CE Marked, ROHS, ANSI

Frequently asked questions

What is the difference between the DA12 and the TCA100?

Both distribute time code, but they are built differently. The TCA100 has two output channels, a high-impedance bridging input of more than 100 kΩ and a 600 Ω output, and its outputs can be transformer isolated. The DA12 has twelve buffered outputs on 50 Ω BNC and no transformer isolation. Choose the TCA100 for a studio where two feeds have to be galvanically separated; choose the DA12 when one source has to reach many receivers.

How many outputs does the TCA100 have?

Two. It is a dual-channel amplifier: channel 1 and channel 2, each on its own BNC and on separate pins of the DB-9 connector, with the level of each channel adjustable from the front panel.

What impedance does the TCA100 use?

The TCA100 does not work with 50 Ω or 75 Ω. Its input is a balanced bridging input of more than 100 kΩ, isolated from chassis ground, and the output impedance is 600 Ω. The output level is adjustable from 1 to 14 V p-p into a 600 Ω load. Tell us which source you are feeding it from and we will confirm the setting.

What is the lead time for this product?

Standard lead time is 8-10 weeks from Masterclock USA. Daylight bv stocks the most common references in Ghent. Contact us for current availability and any rush options.

What warranty do you get on this product?

1 year Daylight warranty + 4 years extra Masterclock warranty on parts and labour (5 years total), via Daylight bv as authorised Masterclock distributor. Carry-in for customers in the EEA, on-site available by prior arrangement. See five-year warranty.

Background in our knowledge base

Deeper explanation of the protocols and concepts behind this product.

Manuals & documentation

User manuals1

Interested?

Request a no-obligation quote for the TCA100. Daylight bv – authorised Masterclock distributor since 2014, with 1 year Daylight warranty + 4 years extra Masterclock warranty and 24/7 support.

Request a quote

What are you looking for?