DA12 Signal Distribution Amplifier

The DA12 is a dual-channel distribution amplifier for time code signals (IRIG-B, SMPTE, EBU).

Masterclock DA12 distribution amplifier with 12 outputs

A single time code input is amplified and distributed to twelve buffered outputs, so one central source can feed multiple displays and devices without the signal loss and reflections you get from T-taps. Standard 1U rack mount, AC power.

Technical specifications

Features
  • One input feeding all twelve outputs, or two inputs each feeding their own bank of six
  • DC coupled, passes both DCLS and AM time code
  • Two output banks that the rear selector links or keeps separate
  • Gain adjustable per output bank
  • Universal AC power for worldwide use
  • 1U steel chassis with rust resistant black powder coat
  • Power LED on the front panel
Physical
  • Size: 43w x 4.31h x 11.5d cm
  • Weight: 0.5 kg
Power
  • Mains powered: 90-240 VAC, 50/60 Hz - power cord supplied with the plug type for your country
  • Power consumption: < 15 watts
Operating Parameters
  • Temperature: 0 to 60°C
  • Humidity: Up to 90% (non-condensing)
Inputs - 2
  • RF
  • Pulse /DC IRIG Time Code
  • AM IRIG Time Code
Outputs - 12
  • RF
  • Pulse /DC IRIG Time Code
  • AM IRIG Time Code
Warranty
  • 1 year Daylight warranty + 4 years extra Masterclock warranty (parts and labour)
Compliance
  • FCC, CE Marked, ROHS, ANSI

Frequently asked questions

How many outputs does the DA12 have?

Twelve. A rear selector chooses between one input driving all twelve outputs, or two inputs each driving their own bank of six.

What is the advantage of a DA12 over T-taps?

Every output is separately buffered and amplified, so each receiver gets a full-strength signal. T-taps split one signal and cause impedance mismatch, reflections and level loss, which gets worse with every receiver you add. For more than two or three receivers a distribution amplifier is the reliable answer. The two banks of six can be linked or kept separate with the rear selector.

Which impedance does the DA12 use?

The input and outputs are 50 Ω on BNC. A 75 Ω coaxial feed connects without difficulty, which is how the unit is normally used in a broadcast installation; for the cleanest signal Masterclock recommends terminating with 50 Ω. Send us your source type and signal level and we will confirm the gain setting for your installation.

What is the lead time for this product?

Standard lead time is 8-10 weeks from Masterclock USA. Daylight bv stocks the most common references in Ghent. Contact us for current availability and any rush options.

What warranty do you get on this product?

1 year Daylight warranty + 4 years extra Masterclock warranty on parts and labour (5 years total), via Daylight bv as authorised Masterclock distributor. Carry-in for customers in the EEA, on-site available by prior arrangement. See five-year warranty.

Manuals & documentation

User manuals1

Interested?

Request a no-obligation quote for the DA12. Daylight bv – authorised Masterclock distributor since 2014, with 1 year Daylight warranty + 4 years extra Masterclock warranty and 24/7 support.